Real spans. Real loads. Real results. Every project below links directly to the calculator so you can run your own numbers for a similar application.

Physical Load Test — 50-Foot Truss

Load Test
The Challenge

Demonstrate real-world structural performance of the TDW centric nodal truss under point loading at midspan. All material specified at minimum grade to establish a conservative performance baseline. No controlled laboratory — real fabrication shop conditions.

The Result

A 50-foot TDW truss fabricated entirely from Grade 50 HSS 1"×0.125" square tube with 0.25" gusset plate was loaded with a 2,400 lb concrete block on a standard 48" pallet at midspan. Measured deflection at the load point was approximately 0.25". No failure. No permanent deformation. Test terminated by equipment capacity, not structural capacity.

50'
Clear Span
36"
Truss Depth
2,400lb
Point Load at Midspan
0.25"
Measured Deflection

Warehouse Distribution — Long Clear Span

Warehouse
The Application

Large-bay warehouse and distribution center construction demands maximum clear span with minimum interior columns, fast erection schedules, and structural systems that can accommodate mechanical and electrical pathways through the truss depth. Standard SJI joists at 6.25 ft O.C. require bridging at every panel point and produce L/240 deflection at best.

The TDW Solution

TDW trusses at 12.5 ft O.C. — half the member count of SJI. Embedded saddle connections at the bearing points. L/480 deflection standard built in. Mechanical and electrical routing through the open web depth. Speed bridging instead of cross bridging. 55% fewer members per bay means less iron in the air and faster erection.

12.5'
TDW Spacing O.C.
55%
Fewer Members vs SJI
L/480
Deflection Standard
100'
Max Clear Span

Grocery & Big Box Retail — Flat Floor System

Retail
The Application

Grocery stores and big box retail require long clear spans with no interior columns, strict floor flatness tolerances, and composite deck systems. SJI joists at L/240 produce deflection that compromises floor flatness and refrigerated case performance. Camber in welded SJI joists generates horizontal arch thrust at supports that is rarely accounted for in standard design.

The TDW Solution

TDW trusses deliver L/480 deflection — twice the code minimum — producing flatter floors and reducing long-term deflection concerns at refrigerated cases, shelving, and equipment. Zero eccentricity at every connection eliminates the horizontal thrust problem inherent in cambered SJI systems. Drop-in embedded saddle bearing with no field welding at the seat.

L/480
vs SJI L/240
2×
Code Minimum Stiffness
0
Eccentricity at Nodes
Gr70
Minimum Steel Grade

Your project starts with a number.

Span, depth, spacing, load. TDW vs SJI side by side. Under 60 seconds.

Open the Calculator

Need Engineering Support?

Our team can provide full design services for your project.